At a glance
- Response Pressure
- 2 mbar (max. 500 mbar)
- Output
- Changeover switch
- Relay Contact Rating
- 6 to 250 V AC, 6 to 50 V DC
- Operating Temperature
- -30 to +80 °C
- Technology
- Pneumatic pressure wave switch
- IP Rating
- Housed version D3-PK1: IP54
Bircher D3-P Pneumatic Pressure Wave Switch (D3 Series)
Price on request
At a glance
- Response Pressure
- 2 mbar (max. 500 mbar)
- Output
- Changeover switch
- Relay Contact Rating
- 6 to 250 V AC, 6 to 50 V DC
- Operating Temperature
- -30 to +80 °C
- Technology
- Pneumatic pressure wave switch
- IP Rating
- Housed version D3-PK1: IP54
Pressure wave switch that turns a press on a pneumatic safety edge on a vehicle door, gate or barrier into an electrical signal. Changeover contact, adjustable set pressure, from 2 mbar up to 500 mbar, 6 to 250 V AC and 1 to 1,000 mA.
D3-P, D3-PB
Include the required quantity and configuration in your quote request. Price and availability will be confirmed in the quotation.
- WarrantyManufacturer warranty under Bircher's terms. Warranty claims
- DeliveryPrice, availability and delivery charges are confirmed in your quotation. Shipping and delivery
Overview
What it is
The D3 series is Bircher’s second pressure wave switch design. It has a two-hole baseplate, adjustable set pressure and a changeover contact, and converts the air pulse from a pressed pneumatic profile into an electrical signal.
What it is used for
Pneumatic safety edges and pressure-sensitive profiles on vehicle doors, gates, roller doors and barriers, where a changeover contact or wider current range than DW40 is needed.
Key features
- Response pressure 2 mbar, maximum pressure 500 mbar.
- Changeover switch for 6 to 250 V AC or 6 to 50 V DC, 1 to 1,000 mA resistive.
- Mechanical service life 10 million switching operations.
- Ambient temperature -30 to +80 °C.
- Two versions: D3-P, and D3-PB with sealed pressure equalisation valve.
Buying considerations
D3-P is also sold pre-fitted in the GEHD3K1 snap-in housing as D3-PK1 (IP54). Choose D3-PB where the equalisation valve must be sealed.
Installation considerations
The D3-P K1 mounting instructions call for the hose to be fully pushed onto the connecting piece without kinks, and include a drilling template. Hoses are 2/4 mm, up to 10 m to the switch.
Compatibility
Works with Bircher DWS pneumatic profiles and the Bircher range of hoses and connection pieces.
Features

Size and fit
- Dimensions
- 43.5 x 35 x 31.8 mm (brochure drawing)
Technical specifications
Key facts
- What is it?
- Safety Edges & MatsBrand Bircher, model D3-P / D3-PB
- What is it used for?
- Pneumatic safety edges on vehicle doors
- Can it be used outdoors?
- IP54
- Which documents are available?
- Brochure, user manual Open documents
- Can SecurityGearHub help with installation?
- Setup guidanceManuals, wiring guides and answers to setup questions. On-site work is arranged separately where available. Ask about installation
- Not stated by the manufacturer
- power, box contents
- Technology
- Pneumatic pressure wave switch
- Application
- Pneumatic safety edges on vehicle doors, gates and barriers
- Response Pressure
- 2 mbar (max. 500 mbar)
- Pressure Equalisation
- 65 ml/min at 2 mbar
- Output
- Changeover switch
- Relay Contact Rating
- 6 to 250 V AC, 6 to 50 V DC; 1 to 1,000 mA (AC/DC resistive)
- Mechanical Service Life
- 10 million switching cycles
- Operating Temperature
- -30 to +80 °C
- Dimensions
- 43.5 x 35 x 31.8 mm (brochure drawing)
- IP Rating
- Housed version D3-PK1: IP54
- Warranty
- Manufacturer warranty under Bircher's terms. How claims work
Product attributes and shipping details
| Brand | Bircher |
|---|---|
| Version | D3-P, D3-PB |
Downloads
Documentation
- Bircher D3-P / D3-PB: Pressure Wave Switches BrochureBrochure · This model · 3.7 MBDownload
User manual
- D3-P K1 Mounting InstructionsUser manual · This model · 1.4 MBDownload
Series documents can differ from your exact model. Report a wrong or missing file
Works with this product
Other models in the series
- Bircher DW40 Pneumatic Pressure Wave Switch (D1 Series)DW40
Why D1-series switch, NO or NC contact, 50 million cycles.
Questions about this product
What is the difference between D3-P and D3-PB?
Both are D3-series switches where pressure actuates the switch. On D3-PB the pressure equalisation valve is sealed, according to the Bircher brochure.
Is there a housed version?
Yes. Bircher lists D3-PK1 (article 209869), a D3-P fitted in the impact-resistant snap-in housing GEHD3K1.
Ask about this modelSetup, compatibility, what is in the box
Answers are automated. Do not enter personal or account details.
Looking for an alternative?
We list alternatives only when we have checked they suit the same job. Compare other models in the category, or ask us to suggest one for your site.