Online checkout is currently closed. Browse products, build your list and request a quotation. Need help? Call or WhatsApp us.Online checkout is currently closed. Call or WhatsApp for enquiries.

  • Sold by Sada Smart Solutions LLP, GSTIN 29AEJFS5796N1ZTSada Smart Solutions LLP

Call or WhatsApp +91 96060 62750 / 62751, Mon to Sat, 9:00 AM to 6:30 PM

At a glance

Door Type
Swing doors, revolving doors
Mounting Height
1.7 to 3.0 m depending on background
Safety Category
PLd (EN ISO 13849-1), SIL2 (EN 61508)
Supply Voltage
15 to 37 V DC / 15 to 26 V AC, 50/60 Hz
IP Rating
IP54 (EN 60529)
Detection Field
471 x 60 mm per US beam at 2.2 m
Bircher logoModel UniScanCurrent model

Bircher UniScan Infrared Safety Sensor for Swing and Revolving Doors

Price on request

At a glance

Door Type
Swing doors, revolving doors
Mounting Height
1.7 to 3.0 m depending on background
Safety Category
PLd (EN ISO 13849-1), SIL2 (EN 61508)
Supply Voltage
15 to 37 V DC / 15 to 26 V AC, 50/60 Hz
IP Rating
IP54 (EN 60529)
Detection Field
471 x 60 mm per US beam at 2.2 m

Infrared safety bar fitted on the leaf of an automatic swing or revolving door so the door stops before it hits a person. 8 switchable beams per unit, EC type-examined to EN 16005 and DIN 18650, mounts 1.7 to 3 m high.

Available in

Version: UniScan I, 350 mm, UniScan II, 750 mm, UniScan II, 900 mm, UniScan II, 1100 mm, Door set 2 x UniScan II, 1100 mm, Door set 2 x UniScan II, 1200 mm

Colour: Silver, Black, White

Include the required quantity and configuration in your quote request. Price and availability will be confirmed in the quotation.

Overview

What it is

UniScan is an AIR (active infrared) presence detector built into a slim aluminium profile that mounts on the door leaf. It uses the triangulation principle with 880 nm infrared light. Each optical unit, called a US beam, projects 8 beams that can be switched individually.

What it is used for

Bircher designs UniScan to protect people at automatic swing doors and revolving doors. On a swing door it monitors the main and secondary closing edges on both sides of the leaf, and its dense field is aimed at small children and people with impaired mobility.

Key features

  • EC type certificate to EN 16005, DIN 18650-1 and EN 12978; PLd to EN ISO 13849-1 and SIL2 to EN 61508
  • Fully automatic teach-in at the press of a key, including mounting height detection
  • Detection zone of 471 x 60 mm per US beam at 2.2 m, response under 50 ms
  • Power saving mode with 5 of 8 beams active as the factory setting
  • Changeover relay output, 40 V DC / 40 V AC, 1 A, with 0 to 10 s hold time

Buying considerations

Choose the version by door leaf width: UniScan I (one US beam, 350 mm) or UniScan II (two US beams) in 750, 900 or 1100 mm, or a door set of two UniScan II units for both sides of the leaf. Profiles come in silver, black or white.

Installation considerations

Mounting height is 1.7 to 3.0 m depending on the background. Up to 4 sensors can be linked on DC supply only. The door loop sets carry the cable from frame to leaf. Protection class is IP54.

Compatibility

Supply 15 to 37 V DC or 15 to 26 V AC (AC only for a single device). The test input supports high or low active and pull up or pull down wiring, so it adapts to most monitored door operators. The RegloBeam 2 remote control can change parameters.

Technical specifications

Key facts

What is it?
Door Activation & Safety SensorsBrand Bircher, model UniScan
What is it used for?
Presence detection on the moving door leaf
How is it powered?
15 to 37 V DC / 15 to 26 V AC, 50/60 Hz
Can it be used outdoors?
IP54
Which documents are available?
User manual, quick start guide, brochure, certificate Open documents
Can SecurityGearHub help with installation?
Setup guidanceManuals, wiring guides and answers to setup questions. On-site work is arranged separately where available. Ask about installation
Not stated by the manufacturer
box contents

RelatedSeriesBircher Scan series, 3 modelsDocumentsAll Bircher documents

General

Technology
Active infrared (AIR), triangulation, 880 nm, 8 beams per US beam
Application
Presence detection on the moving door leaf
Door Type
Swing doors, revolving doors
Detection Field
471 x 60 mm per US beam at 2.2 m (each beam 30 x 60 mm)
Response Time
< 50 ms; test signal < 30 ms (typical 3 ms)
Relay Contact Rating
40 V DC / 40 V AC, 1 A
Configuration
Key teach-in or RegloBeam 2 remote control
Output
Changeover relay, hold time 0 to 10 s

Input

Supply Voltage
15 to 37 V DC / 15 to 26 V AC, 50/60 Hz (AC only for single device)
Power Consumption
Max. 3.3 W (138 mA at 24 V per unit); making current max. 500 mA

Environment

IP Rating
IP54 (EN 60529)
Operating Temperature
-20 to +60 °C

Physical

Mounting Height
1.7 to 3.0 m depending on background
Housing Material
Aluminium profile, PMMA front cover (black)
Colour
Silver, black, white
Dimensions
US beam 300 x 31 x 20 mm
Weight
US beam 90 g; UniScan II 1100 mm 910 g

Approvals

Safety Category
PLd (EN ISO 13849-1), SIL2 (EN 61508)
Standards
EC type certificate: EN 16005, DIN 18650-1, EN 12978, EN ISO 13849-1, EN 61508
Warranty
Manufacturer warranty under Bircher's terms. How claims work
Product attributes and shipping details
Brand

Bircher

Version

UniScan I, 350 mm, UniScan II, 750 mm, UniScan II, 900 mm, UniScan II, 1100 mm, Door set 2 x UniScan II, 1100 mm, Door set 2 x UniScan II, 1200 mm

Colour

Silver, Black, White

Downloads

Documentation

  • UniScan BrochurePublicBrochure · This model · 3.0 MB
    Download
Certificate and compliance document (1)
  • UniScan / US beam EU Declaration of ConformityPublicCertificate · This model · 390.5 KB
    Download

User manual

  • UniScan Operating InstructionsPublicUser manual · This model · 1.3 MB
    Download
  • UniScan QuickstartPublicQuick start guide · This model · 247.6 KB
    Download

Series documents can differ from your exact model. Report a wrong or missing file

Works with this product

Relevant accessories

Replacements and alternatives

Questions about this product

Which UniScan length should I order?

Match the profile to the door leaf: UniScan I is 350 mm with one optical unit; UniScan II comes in 750, 900 and 1100 mm with two units. Door sets contain two UniScan II bars for both sides of the leaf.

Is UniScan certified to EN 16005?

Bircher lists an EC type certificate to EN 16005, DIN 18650-1, EN 12978, EN ISO 13849-1 and EN 61508.

Can several UniScan sensors be connected together?

Yes, up to 4 units can be linked and synchronised, with DC supply only.

Ask about this modelSetup, compatibility, what is in the box
Downloads

Answers are automated. Do not enter personal or account details.

Price on requestRequest a quotation