At a glance

Detection Range
≤60m2
Dimensions
103 mm × 104 mm × 46 mm
Installation Method
Ceiling or wall Mounting
Operating Voltage
9 V DC~15 V DC
Dahua logoModel FAD201A

Dahua FAD201A 4-Wire Non-Addressable Smoke Detector

₹1,882 Incl. GST

₹1,595 + 18% GST

At a glance

Detection Range
≤60m2
Dimensions
103 mm × 104 mm × 46 mm
Installation Method
Ceiling or wall Mounting
Operating Voltage
9 V DC~15 V DC

Smoke detector for the fire zone of an intrusion alarm panel in homes, shops and offices, closing a relay to signal the panel when it senses smoke. Photoelectric, 4-wire, 9 to 15 V DC, covers up to 60 m².

Add to quote
  • WarrantyManufacturer warranty under Dahua's terms. Warranty claims
  • DeliveryPrice, availability and delivery charges are confirmed in your quotation. Shipping and delivery
  • InstallationCeiling or wall Mounting

Overview

The Dahua FAD201A is a 4-wire, non-addressable smoke detector for the fire zone of a wired alarm panel. An infrared photoelectric chamber senses smoke, a microcontroller filters the signal to cut false alarms, and a normally open relay closes to signal the panel while the red LED flashes quickly. It suits a home, shop, office, pantry or small server room that wants smoke warning through its intrusion alarm rather than a separate fire panel.

Is it right for you?

  • It suits a wired intrusion panel with a 24-hour fire zone and a 12 V auxiliary output, such as the Dahua ARC2008C-V3 or ARC2016C-V3.
  • It is a conventional detector for alarm-panel use, not a listed component of an addressable fire alarm system, so check local fire rules for your building.
  • One detector covers up to 60 m², so plan one per room or section.
  • For a Dahua wireless alarm, the HY-SA21A-W2 wireless smoke alarm is the matching detector.

Key features

  • Infrared photoelectric sensing.
  • Microcontroller (MCU) processing to reduce false alarms.
  • Normally open (NO) relay output, so it wires to an ordinary panel zone.
  • Red LED flashes every 9 seconds in standby and quickly on alarm.
  • Coverage up to 60 m².
  • Runs on 9 to 15 V DC, drawing 2 mA or less in standby and 30 mA or less in alarm.
  • Ceiling or wall mounting; ABS housing, 103 x 104 x 46 mm, about 120 g.
  • Operating range -10 to 55 °C and up to 95% humidity.

What else you need

A wired alarm panel with a 24-hour fire zone, a 9 to 15 V DC supply, normally the panel’s 12 V auxiliary output, and 4-wire cable: a pair for power and a pair for the relay.

Installation

An alarm installer should fit it. Mount it on the ceiling or wall, run the 4-wire cable to the panel, connect power to the auxiliary output and the relay to a 24-hour fire zone, then test it at the panel.

Before you buy

  • Not a listed component of an addressable fire alarm system; check local fire code requirements.
  • It needs a separate power pair as well as the zone pair (4-wire).

Features

Dahua FAD201A 4-Wire Non-Addressable Smoke Detector, dimension drawing
Check the datasheet for tolerances.

Size and fit

Dimensions
103 mm × 104 mm × 46 mm
Weight
About 120g

Technical specifications

Key facts

What is it?
Fire & Environmental DetectorsBrand Dahua, model FAD201A
How is it powered?
9 V DC~15 V DC
Which documents are available?
Datasheet (2), installation / drawing, online specifications Open documents
Can SecurityGearHub help with installation?
Setup guidanceManuals, wiring guides and answers to setup questions. On-site work is arranged separately where available. Ask about installation
Not stated by the manufacturer
outdoor rating, box contents

RelatedDocumentsAll Dahua documents

Model
FAD201A
Operating Voltage
9 V DC~15 V DC
Work Principle
Photoelectric
Standby Current
≤2mA
Alarm Current
≤30mA
LED Status
Normal: red LED flashes every 9 seconds; Alarm: red LED flashes quickly
Environment
Temperature: -10 °C~55 °C Relatively humidity: ≤95%
Alarm Output
NO relay out
Detection Range
≤60m2
Dimensions
103 mm × 104 mm × 46 mm
Weight
About 120g
Installation Method
Ceiling or wall Mounting
Material
ABS
Quality Level
Industral
Warranty
Manufacturer warranty under Dahua's terms. How claims work
Product attributes and shipping details
Brand

Dahua

Downloads

Documentation

  • Dahua FAD201A datasheetPublicDatasheet · This model · 668.9 KB
    Download
  • HY-SA-K930 4-wire Non-addressable Smoke Detector-V1.0.0PublicDatasheet · This model · materialfile.dahuasecurity.com
    Download
  • Dahua FAD201A product pagePublicOnline specifications · This model · dahuasecurity.com
    View official page

Installation guide

  • FAD201A DIMENSIONSPublicInstallation / drawing · This model · materialfile.dahuasecurity.com
    Download

Series documents can differ from your exact model. Report a wrong or missing file

Questions about this product

What power does it need?

9 to 15 V DC, usually from the panel's 12 V auxiliary output. It draws 2 mA or less in standby and 30 mA or less in alarm.

How much area does one cover?

Up to 60 m².

Which panels does it work with?

Any wired panel with a 24-hour fire zone, such as the Dahua ARC2008C-V3 or ARC2016C-V3.

Does it sound an alarm on its own?

Not stated by the manufacturer. It signals the panel through its relay, and the panel's siren raises the alarm.

Can it be used outdoors?

Not stated by the manufacturer. Its operating range is -10 to 55 °C and up to 95% humidity.