At a glance
- Rated Output Current
- 0 to 20 A continuous
- Input Voltage Range
- 12 V DC nominal (9 V to 14 V DC), 2 input channels
- Redundancy
- 1+1 redundancy, supports N+1 redundancy
- Voltage Drop (max.)
- 0.2 V
- Operating Temperature
- -40 °C to +80 °C
- Output Voltage
- 12 V DC system
MEAN WELL ERDN20-12 Power Supply Accessory, 12 V, 20 A redundancy module
Price on request
At a glance
- Rated Output Current
- 0 to 20 A continuous
- Input Voltage Range
- 12 V DC nominal (9 V to 14 V DC), 2 input channels
- Redundancy
- 1+1 redundancy, supports N+1 redundancy
- Voltage Drop (max.)
- 0.2 V
- Operating Temperature
- -40 °C to +80 °C
- Output Voltage
- 12 V DC system
Joins two DC power supplies so the load keeps running if one fails and signals which one has failed, for automation and control systems. Power supply accessory, 12 V, 20 A redundancy module. Supports 1+1 and N+1 redundancy systems.
Part of the MEAN WELL ERDN20 series. Compare all 4 models
Include the required quantity and configuration in your quote request. Price and availability will be confirmed in the quotation.
- WarrantyManufacturer warranty under MEAN WELL's terms: 3 years. Warranty claims
- DeliveryPrice, availability and delivery charges are confirmed in your quotation. Shipping and delivery
Overview
What it is
The MEAN WELL ERDN20-12 is a power supply accessory from the ERDN20 series (20 A Enclosed Type Redundancy Module), rated 12 V, 20 A redundancy module.
What it is used for
Joins the outputs of two (or N+1) DC power supplies through MOSFET isolation so the load keeps running if one supply fails, and signals which input has failed. MEAN WELL lists applications such as industrial control systems, semiconductor fabrication equipment, factory automation, electro-mechanical apparatus.
Key features
- Supports 1+1 and N+1 redundancy systems.
- 2 input channels and 1 output.
- For 5 V / 12 V / 24 V / 48 V systems, output current up to 20 A.
- Operating temperature -40 °C to +80 °C (derating above +60 °C).
- Built-in 2 channel DC OK signal and alarm relay contact.
- Cooling by free air convection.
Key Specifications
- Rated Output Current: 0 to 20 A continuous; peak 30 A for 5 s.
- Input Voltage Range: 12 V DC nominal (9 V to 14 V DC), 2 input channels.
- Redundancy: 1+1 redundancy, supports N+1 redundancy.
- Voltage Drop (max.): 0.2 V.
- Operating Temperature: -40 °C to +80 °C (see derating curve).
Buying considerations
Size the unit with headroom above the connected load and check the derating information in the datasheet for high ambient temperature or low input voltage. Other models in the same series are listed on this page.
Installation considerations
MEAN WELL treats this unit as a component of the final equipment, so approvals and EMC performance should be confirmed for the complete installation. Wiring and safety details are in the official datasheet linked below.
Technical specifications
Key facts
- What is it?
- Power supply accessoryBrand MEAN WELL, model ERDN20-12
- What does it output?
- 12 V DC system, 0 to 20 A continuous
- What input does it accept?
- 12 V DC nominal (9 V to 14 V DC), 2 input channels
- Which documents are available?
- Datasheet, certificate Open documents
RelatedSeriesMEAN WELL ERDN20 series, 4 modelsDocumentsAll MEAN WELL documents
Output
- Rated Output Current
- 0 to 20 A continuous; peak 30 A for 5 s
- Output Voltage
- 12 V DC system (input voltage minus up to 0.2 V drop)
- Efficiency (typ.)
- 98%
Input
- Input Voltage Range
- 12 V DC nominal (9 V to 14 V DC), 2 input channels
- Input Voltage Alarm
- below 8.5 V or above 14.7 V (±5%)
Protection
- Withstand Voltage
- IP/OP to chassis: 0.5 kV AC; IP/OP to relay: 0.5 kV AC; relay to chassis: 0.5 kV AC
Environment
- Operating Temperature
- -40 °C to +80 °C (see derating curve)
- Operating Humidity
- 5% to 95% RH non-condensing
- Cooling
- Free air convection
Physical
- Dimensions
- 82 x 99 x 36 mm (W x D x H)
- Weight
- 0.206 kg
Approvals
- MTBF
- 1853.5K hrs min. Telcordia SR-332 (Bellcore); 378.7K hrs min. MIL-HDBK-217F (25 °C)
Other
- Rated Input Current
- 0 to 20 A per input continuous; peak 30 A per input for 5 s
- Voltage Drop (max.)
- 0.2 V
- Redundancy
- 1+1 redundancy, supports N+1 redundancy
- Standby Power Loss (typ.)
- 1.5 W
- Signals
- DC OK relay contacts for 2 channels, 30 V DC / 1 A resistive; green LED OK
- Input Reverse Voltage (max.)
- 40 V DC
- Series
- ERDN20
- Warranty
- Manufacturer warranty under MEAN WELL's terms: 3 years. How claims work
Product attributes and shipping details
| Brand | MEAN WELL |
|---|
Downloads
Documentation
- ERDN20 series datasheetDatasheet · Family · meanwell.comDownload
Certificate and compliance document (1)
- ERDN20 CE declaration of conformityCertificate · Family · meanwell.comDownload
Series documents can differ from your exact model. Report a wrong or missing file
Questions about this product
What input voltage does the ERDN20-12 accept?
MEAN WELL lists 12 V DC nominal (9 V to 14 V DC), 2 input channels for this model.
Ask about this modelSetup, compatibility, what is in the box
Answers are automated. Do not enter personal or account details.
Looking for an alternative?