At a glance
- Channels
- 1 or 2 loops
- Supply Voltage
- 24 V DC -10% to +20%, or 230 V AC ±10% 50 Hz
- Loop Inductance
- 20 to 1,000 µH
- Output
- Relay outputs
- Mounting
- DIN rail or 11-pin plug-in base ES12
- IP Rating
- IP20 (IEC 60529)
Bircher ProLoop Lite Induction Loop Detector
Price on request
At a glance
- Channels
- 1 or 2 loops
- Supply Voltage
- 24 V DC -10% to +20%, or 230 V AC ±10% 50 Hz
- Loop Inductance
- 20 to 1,000 µH
- Output
- Relay outputs
- Mounting
- DIN rail or 11-pin plug-in base ES12
- IP Rating
- IP20 (IEC 60529)
Compact loop detector that senses vehicles over a road loop to open sliding gates and barriers or trigger car park ticket machines. LCD setup, 9 sensitivity steps, 24 V DC or 230 V AC, 1 or 2 channels, DIN rail or 11-pin versions.
Housing: DIN rail, 11-pin plug-in
Channels: 1, 2
Supply Voltage: 24 V DC, 230 V AC
Include the required quantity and configuration in your quote request. Price and availability will be confirmed in the quotation.
- WarrantyManufacturer warranty under Bircher's terms. Warranty claims
- DeliveryPrice, availability and delivery charges are confirmed in your quotation. Shipping and delivery
Overview
What it is
ProLoop Lite is Bircher’s compact standard loop detector, described in the Sensorama brochure as the compact version of ProLoop2. It evaluates a wire loop in the road and switches relays when a metal vehicle is over the loop.
What it is used for
Opening sliding gates and barriers, triggering ticket machines and presence checks at car park entries where the full ProLoop2 feature set is not needed.
Key features
- LCD display and two push buttons, same operating concept as ProLoop2.
- Inductance range 20 to 1,000 µH, ideal 80 to 300 µH, with isolation transformer.
- Sensitivity 0.01 to 1.00% in 9 steps and Automatic Sensitivity Boost.
- Hold, on-delay, off-delay and pulse on entry or exit modes, 0.1 s to 99 h.
- Relay outputs rated 240 V AC, 2 A (AC-1) or 30 V DC, 1 A (DC-1).
Buying considerations
Supply options are 24 V DC or 230 V AC at 50 Hz; check that this suits your mains supply. The data sheets do not list the power-fail memory or alarm relay found on ProLoop2, so choose ProLoop2 when those are required.
Installation considerations
IP20 device for a cabinet or barrier housing, -20 to +60 °C. 11-pin versions plug into an ES12 base. Each channel needs its own induction loop.
Compatibility
Works with Bircher pre-assembled loops and site-laid loops within the stated inductance range, and with any barrier or gate controller that accepts a relay contact.
Features

Size and fit
- Mounting
- DIN rail or 11-pin plug-in base ES12
- Dimensions
- DIN: 22.5 x 92 x 85 mm; 11-pin: 36 x 74 x 88 mm
- Weight
- 150 to 280 g depending on version
Technical specifications
Key facts
- What is it?
- Loop Detectors & Vehicle SensorsBrand Bircher, model ProLoop Lite
- What is it used for?
- Vehicle detection at gates, barriers and car parks
- How is it powered?
- 24 V DC -10% to +20%, or 230 V AC ±10% 50 Hz
- Can it be used outdoors?
- IP20
- Which accessories may be required?
- Pre-assembled induction loop SF; Plug-in base ES12Some depend on the installation. See Works with for the conditions.
- Which documents are available?
- User manual (2), datasheet, installation guide, certificate Open documents
- Can SecurityGearHub help with installation?
- Setup guidanceManuals, wiring guides and answers to setup questions. On-site work is arranged separately where available. Ask about installation
- Not stated by the manufacturer
- box contents
General
- Technology
- Inductive loop detection, frequency modulation
- Application
- Vehicle detection at gates, barriers and car parks
- Channels
- 1 or 2 loops (2 loops in DIN rail housing only)
- Loop Inductance
- 20 to 1,000 µH (ideal 80 to 300 µH)
- Operating Frequency
- 16 to 120 kHz, 4 steps
- Relay Contact Rating
- AC-1: 240 V AC, 2 A; DC-1: 30 V DC, 1 A
- Response Time
- Channel switching time 25 ms (1-loop data sheet)
- Configuration
- LCD display and 2 push buttons
- Output
- Relay outputs
Input
- Supply Voltage
- 24 V DC -10% to +20%, or 230 V AC ±10% 50 Hz
- Power Consumption
- 2 W (1.24DC data sheet)
Environment
- Operating Temperature
- -20 to +60 °C
- IP Rating
- IP20 (IEC 60529)
Physical
- Mounting
- DIN rail or 11-pin plug-in base ES12
- Dimensions
- DIN: 22.5 x 92 x 85 mm; 11-pin: 36 x 74 x 88 mm
- Weight
- 150 to 280 g depending on version
- Housing Material
- PA black / grey (DIN)
Approvals
- Standards
- RED 2014/53/EU
- Warranty
- Manufacturer warranty under Bircher's terms. How claims work
Product attributes and shipping details
| Brand | Bircher |
|---|---|
| Detection Zones | 1, 2 |
| Housing | DIN rail, 11-pin plug-in |
| Channels | 1, 2 |
| Supply Voltage | 24 V DC, 230 V AC |
Downloads
Documentation
- ProLoop Lite 1.24DC Data SheetDatasheet · This model · 222.1 KBDownload
Certificate and compliance document (1)
- ProLoop Lite EU Declaration of ConformityCertificate · This model · 385.7 KBDownload
User manual
Installation guide
- Bircher ProLoop installation guide (Loop Installation Instructions)Installation guide · Family · 434.6 KBDownload
Series documents can differ from your exact model. Report a wrong or missing file
Works with this product
Relevant accessories
- Bircher SF Pre-Assembled Induction Loop for ProLoop DetectorsSF pre-assembled induction loop
Why Each channel needs an induction loop. Condition: Unless a loop is laid on site.
- Bircher ES12 11-Pin Plug-in Base for ProLoop Loop DetectorsES12
Why 11-pin versions are pluggable for 11-pin base ES 12. Condition: 1.S versions only.
Price on requestAdd to quote
Upgrades
- Bircher ProLoop2 Induction Loop Detector, 1 or 2 ChannelProLoop2
Why Adds alarm output option, power-fail memory and LVAC supply. Condition: When those functions are needed.
Questions about this product
What is the difference between ProLoop Lite and ProLoop2?
Bircher calls ProLoop Lite the compact standard version of ProLoop2. The Lite data sheets offer 24 V DC or 230 V AC only and do not list the alarm output or power-fail memory of ProLoop2.
Is there a 2-channel ProLoop Lite?
Yes, in DIN rail housing: 2.24DC and 2.230AC. The 11-pin versions are 1-channel only.
Ask about this modelSetup, compatibility, what is in the box
Answers are automated. Do not enter personal or account details.
Looking for an alternative?
We list alternatives only when we have checked they suit the same job. Compare other models in the category, or ask us to suggest one for your site.