Online checkout is currently closed. Browse products, build your list and request a quotation. Need help? Call or WhatsApp us.Online checkout is currently closed. Call or WhatsApp for enquiries.

  • Sold by Sada Smart Solutions LLP, GSTIN 29AEJFS5796N1ZTSada Smart Solutions LLP

Call or WhatsApp +91 96060 62750 / 62751, Mon to Sat, 9:00 AM to 6:30 PM

At a glance

Channels
1 or 2 loops
Supply Voltage
24 V AC/DC
Loop Inductance
20 to 1,000 µH
Output
2 relay outputs
Mounting
DIN rail or 11-pin plug-in base ES12
IP Rating
IP20
Bircher logoModel ProLoop2Current model

Bircher ProLoop2 Induction Loop Detector, 1 or 2 Channel

Price on request

At a glance

Channels
1 or 2 loops
Supply Voltage
24 V AC/DC
Loop Inductance
20 to 1,000 µH
Output
2 relay outputs
Mounting
DIN rail or 11-pin plug-in base ES12
IP Rating
IP20

Detector for a wire loop in the road that senses vehicles, from bicycles to trucks, to open gates and barriers, trigger ticket machines or protect bollards. 1 or 2 channels, LCD display, direction logic on 2-loop units, DIN rail or 11-pin housing.

Available in

Housing: DIN rail, 11-pin plug-in

Channels: 1, 2

Supply Voltage: 24 V AC/DC, 100-240 V AC, 230 V AC

Alarm Output: No, Yes

Include the required quantity and configuration in your quote request. Price and availability will be confirmed in the quotation.

Overview

What it is

ProLoop2 is an inductive loop detector. It drives a wire loop laid in the road, measures the change in inductance when a metal vehicle passes over it, and switches relay outputs. It detects everything from bicycles to trucks with trailers.

What it is used for

Typical uses are opening and closing sliding gates and boom barriers, triggering ticket dispensers at car parks, protecting retractable bollards and controlling gates with traffic lights. Two-loop versions offer a direction logic mode, where the output depends on which loop the vehicle crosses first.

Key features

  • LCD display and two push buttons for setup, with on-screen reading of loop inductance in µH.
  • Inductance range 20 to 1,000 µH, ideal 80 to 300 µH, with an isolation transformer between loop and detector.
  • Sensitivity in 9 steps from 0.01 to 1.00%, plus Automatic Sensitivity Boost for high-bed vehicles.
  • Hold, on-delay, off-delay and pulse on entry or exit modes, with times from 0.1 s to 99 h.
  • Power fail function that stores the loop reference during an outage.
  • Last five error codes stored.

Buying considerations

Choose the housing (DIN rail or 11-pin plug-in), one or two loops, and the supply: 24 V AC/DC, 100 to 240 V AC (LVAC) or 230 V AC (11-pin only). The .A versions add a separate alarm relay. 11-pin versions are supplied without the ES12 plug-in base.

Installation considerations

The detector is IP20 and must sit inside a control cabinet or barrier housing. Each channel needs its own induction loop; Bircher’s loop installation guide covers groove depth, turns and feeder twisting.

Compatibility

Relay outputs rated 240 V AC, 2 A (AC-1) or 30 V DC, 1 A connect to barrier, gate and bollard controllers. The 11-pin version plugs onto existing ES12 bases for retrofits.

Technical specifications

Key facts

What is it?
Loop Detectors & Vehicle SensorsBrand Bircher, model ProLoop2
What is it used for?
Vehicle detection at gates, barriers, car parks and bollards
How is it powered?
24 V AC/DC
Can it be used outdoors?
IP20
Which accessories may be required?
Pre-assembled induction loop SF; Plug-in base ES12Some depend on the installation. See Works with for the conditions.
Which documents are available?
User manual, brochure, datasheet, installation guide, certificate Open documents
Can SecurityGearHub help with installation?
Setup guidanceManuals, wiring guides and answers to setup questions. On-site work is arranged separately where available. Ask about installation
Not stated by the manufacturer
box contents

RelatedDocumentsAll Bircher documents

General

Technology
Inductive loop detection, frequency modulation
Application
Vehicle detection at gates, barriers, car parks and bollards
Channels
1 or 2 loops
Loop Inductance
20 to 1,000 µH (ideal 80 to 300 µH)
Operating Frequency
16 to 120 kHz, 4 steps
Relay Contact Rating
AC-1: 240 V AC, 2 A; DC-1: 30 V DC, 1 A; alarm relay 40 V, 0.3 A
Response Time
Channel switching time 25 ms (1-loop), 50 ms (2-loop)
Max. Vehicle Speed
50 km/h with suitable loop
Loop Supply Cable
1.5 mm², min. 20 twists per metre, max. 100 m at 20 to 40 µH, max. 200 m above 40 µH
Configuration
LCD display and 2 push buttons
Output
2 relay outputs; .A versions add an alarm relay

Input

Supply Voltage
24 V AC/DC; 100 to 240 V AC (LVAC); 230 V AC (11-pin)
Power Consumption
DIN 24 V: max. 1.5 W DC / 2 W AC; LVAC: max. 2.9 W; 11-pin 24 V: 1.3 W DC / 1.8 W AC

Environment

Operating Temperature
-20 to +70 °C (data sheets)
IP Rating
IP20

Physical

Mounting
DIN rail or 11-pin plug-in base ES12
Dimensions
DIN: 22.5 x 92 x 85 mm; 11-pin: 38 x 74 x 88 mm (W x H x D, data sheets)

Approvals

Standards
RED 2014/53/EU
Warranty
Manufacturer warranty under Bircher's terms. How claims work
Product attributes and shipping details
Brand

Bircher

Detection Zones

1, 2

Gate Type

Bollard, Boom Barrier, Sliding gate

Housing

DIN rail, 11-pin plug-in

Channels

1, 2

Supply Voltage

24 V AC/DC, 100-240 V AC, 230 V AC

Alarm Output

No, Yes

Downloads

Documentation

  • ProLoop2 BrochurePublicBrochure · This model · 3.0 MB
    Download
  • ProLoop2 1.24ACDC Data SheetPublicDatasheet · This model · 233.3 KB
    Download
Certificate and compliance document (1)
  • ProLoop2 EU Declaration of ConformityPublicCertificate · This model · 387.2 KB
    Download

User manual

  • ProLoop2 ManualPublicUser manual · This model · 1.0 MB
    Download

Installation guide

  • Bircher ProLoop installation guide (Loop Installation Instructions)PublicInstallation guide · Family · 434.6 KB
    Download

Series documents can differ from your exact model. Report a wrong or missing file

Works with this product

Relevant accessories

Replacements and alternatives

Questions about this product

Which ProLoop2 version should I choose for a single barrier with one loop?

A 1-channel version. Pick the supply that matches your controller: 24 V AC/DC, 100 to 240 V AC (LVAC, DIN rail) or 230 V AC (11-pin plug-in).

Is the induction loop included?

No. Bircher sells pre-assembled loops separately in 6, 8, 10 and 12 m circumferences, or a loop can be laid on site following the Bircher loop installation guide.

Does the 11-pin version include the socket?

No. Bircher lists the 11-pin units as without plug-in base; the ES12 base (article 209745) is ordered separately.

Can ProLoop2 detect the direction of a vehicle?

Yes, on 2-loop devices. In direction logic mode output 1 switches for travel from loop 1 to loop 2 and output 2 for the opposite direction.

Ask about this modelSetup, compatibility, what is in the box
Downloads

Answers are automated. Do not enter personal or account details.

Price on requestRequest a quotation