Online checkout is currently closed. Browse products, build your list and request a quotation. Need help? Call or WhatsApp us.Online checkout is currently closed. Call or WhatsApp for enquiries.

  • Sold by Sada Smart Solutions LLP, GSTIN 29AEJFS5796N1ZTSada Smart Solutions LLP

Call or WhatsApp +91 96060 62750 / 62751, Mon to Sat, 9:00 AM to 6:30 PM

At a glance

Activation
No-touch, 0.1 to 10 cm detection range
Terminals
+12V, GND, NO, NC, COM
Contact Rating
3 A at 36 V DC max
Dimensions
86 x 86 x 35 mm
Suitable Door
Hollow door
MORX logoModel MNT-2

MORX MNT-2 No-Touch Exit Button, Stainless Steel (NO/NC/COM)

₹453 Incl. GST

₹384 + 18% GST

At a glance

Activation
No-touch, 0.1 to 10 cm detection range
Terminals
+12V, GND, NO, NC, COM
Contact Rating
3 A at 36 V DC max
Dimensions
86 x 86 x 35 mm
Suitable Door
Hollow door

No-touch exit button for clinics, labs and busy entrances: a hand held 0.1 to 10 cm from the sensor releases the door. 86 x 86 mm stainless steel plate, NO, NC and COM outputs rated 3 A at 36 V DC, with a 12 V supply terminal.

Add to quote

Overview

The MORX MNT-2 is a no-touch exit button: a hand held 0.1 to 10 cm from the sensor window releases the door, so nobody presses anything to leave. Its 86 x 86 x 35 mm stainless steel plate is marked “No Touch” and “EXIT”, and it suits hospitals, clinics, laboratories, pharmaceutical and food areas, public buildings and busy office entrances on card or biometric access control.

Is it right for you?

  • Suits hygiene-sensitive and high-traffic doors where hand contact should be avoided.
  • Suits doors with a 12 V DC supply nearby, since the sensor needs power as well as the switched contacts.
  • Suits a hollow door or partition with a cavity or back box for an 86 x 86 mm plate.
  • If no supply is available at the door, a mechanical button such as the MORX MS-1 needs none.

Key features

  • Detection range of 0.1 to 10 cm, so a hand wave close to the plate opens the door without false triggers from people walking past.
  • Terminals for +12V, GND, normally open (NO), normally closed (NC) and common (COM).
  • Contact rating of 3 A at 36 V DC maximum.
  • Tested to 1,000,000 operations.
  • Stainless steel panel; rated for -10 to 55 °C and 0 to 95% relative humidity, non-condensing.

What else you need

  • A 12 V DC feed for the sensor, which can come from the same access control power supply that runs the lock, such as the MORX Box+SMPS (12 V, 3.5 A); check the total current of sensor plus lock against the supply.
  • An access controller or standalone reader with an exit input, or a lock supply to switch within 3 A at 36 V DC.
  • A four-core cable (five if NC is used).
  • A cavity or back box behind the plate.

Installation

An access control installer should fit it. The plate is fixed over a cavity or back box, the +12V and GND terminals are wired to the 12 V supply, and the NO or NC and COM contacts are run to the controller exit input or the lock circuit.

Before you buy

  • It needs a 12 V DC feed as well as the switched pair, so plan a four- or five-core cable.
  • Made for hollow doors: a solid wall needs a back box.

Technical specifications

Key facts

What is it?
Exit buttonBrand MORX, model MNT-2
Which documents are available?
Datasheet Open documents
Can SecurityGearHub help with installation?
Setup guidanceManuals, wiring guides and answers to setup questions. On-site work is arranged separately where available. Ask about installation

RelatedGuideAccess control door setup checklistDocumentsAll MORX documents

Activation
No-touch, 0.1 to 10 cm detection range
Terminals
+12V, GND, NO, NC, COM
Contact Rating
3 A at 36 V DC max
Panel Material
Stainless steel panel, steel button
Dimensions
86 x 86 x 35 mm
Mechanical Life
1,000,000 operations (tested)
Suitable Door
Hollow door
Operating Temperature
-10 to 55 °C
Operating Humidity
0 to 95% RH, non-condensing
Warranty
Manufacturer warranty under MORX's terms. How claims work
Product attributes and shipping details
Brand

MORX

Downloads

Documentation

  • MORX MNT-2 No Touch Exit Button specification sheetPublicDatasheet · This model · 1.1 MB
    Download

Series documents can differ from your exact model. Report a wrong or missing file

Works with this product

Relevant accessories

Replacements and alternatives

Questions about this product

Does the MNT-2 need power?

Yes. It has +12V and GND terminals for a 12 V DC feed, in addition to the NO, NC and COM output terminals.

How close does a hand need to be?

Within 0.1 to 10 cm of the sensor window.

Can it switch an EM lock directly?

Yes, within 3 A at 36 V DC, using the NC contact to break a fail-safe lock supply, or it can signal a controller exit input.

Can the 12 V come from the lock supply?

Yes. The same access control power supply that runs the lock can feed the sensor; check the total current against the supply rating.

Ask about this modelDoor fit, access methods, installation
Downloads

Answers are automated. Do not enter personal or account details.

₹453incl. GST